AD: ATR-GIE Avions de Transport Régional Airplanes

AD 2021-09-18 Requires Modifying The Electrical Harness Routes And De-Icing Pipe Coupling Installations

The FAA is adopting a new airworthiness directive (AD) for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

This AD was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. This AD requires modifying the electrical harness routes and de-icing pipe coupling installations, as specified in a European Union Aviation Safety Agency (EASA) AD, which is incorporated by reference. The FAA is issuing this AD to address the unsafe condition on these products. This AD is effective July 1, 2021.

Supplementary Information: The EASA, which is the Technical Agent for the Member States of the European Union, has issued EASA AD 2020-0227, dated October 19, 2020 (EASA AD 2020-0227) (also referred to as the Mandatory Continuing Airworthiness Information, or the MCAI), to correct an unsafe condition for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

The FAA issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 by adding an AD that would apply to certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes. The NPRM published in the Federal Register on February 22, 2021 (86 FR 10491). The NPRM was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. The NPRM proposed to require modifying the electrical harness routes and de-icing pipe coupling installations, as specified in EASA AD 2020-0227.

The FAA is issuing this AD to address chafing damage on an electrical harness bundle, which could result in wire failure and a short circuit, an uncontrolled fire, and consequent loss of multiple systems, possibly resulting in reduced controllability of the airplane. See the MCAI for additional background information.

FMI: www.regulations.gov

Advertisement

More News

Airborne-Flight Training 05.09.24: ERAU at AIAA, LIFT Diamond Buy, Epic A&P

Also: Vertical Flight Society, NBAA Maintenance Conference, GA Honored, AMT Scholarship For the first time, students from Embry-Riddle’s Daytona Beach, Florida, campus took t>[...]

ANN's Daily Aero-Term (05.07.24): Hazardous Weather Information

Hazardous Weather Information Summary of significant meteorological information (SIGMET/WS), convective significant meteorological information (convective SIGMET/WST), urgent pilot>[...]

Aero-News: Quote of the Day (05.07.24)

"The need for innovation at speed and scale is greater than ever. The X-62A VISTA is a crucial platform in our efforts to develop, test and integrate AI, as well as to establish AI>[...]

NTSB Final Report: Cessna 150

(FAA) Inspector Observed That Both Fuel Tanks Were Intact And That Only A Minimal Amount Of Fuel Remained In Each Analysis: According to the pilot, approximately 8 miles from the d>[...]

Aero-News: Quote of the Day (05.08.24)

“Pyka’s Pelican Cargo is unlike any other UAS solution on the market for contested logistics. We assessed a number of leading capabilities and concluded that the Pelica>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC