Thu, Feb 10, 2005

CASA Urgent AD: Boeing

A D Number: AD/B737/125
Manufacturer:
Boeing
Subject: Center Wing Fuel Tank Float Switch Wiring
Applicability: Model 737-200, -200C, -300, -400 and -500 series aeroplanes, on which center wing fuel tanks are activated.
Requirement: Accomplish the following on Model 737-200, -300, -400 and -500 series airplanes having line numbers 1 to 3108 inclusive.
Summary: Remove the fuelling float switch and wiring from the center fuel tank and perform a detailed visual inspection of the float switch wiring, in accordance with Boeing Alert Service Bulletin (ASB) 737-28A1132 dated 2 December 1998 or Revision 1 dated 15 January 1999 or Revision 2 dated 17 June 1999, to detect discrepancies (i.e. evidence of electrical arcing; exposure of the copper conductor; presence or scent of fuel on the electrical wiring; or worn insulation).

FMI: www.casa.gov.au

Advertisement

More News

Airborne-Flight Training 05.09.24: ERAU at AIAA, LIFT Diamond Buy, Epic A&P

Also: Vertical Flight Society, NBAA Maintenance Conference, GA Honored, AMT Scholarship For the first time, students from Embry-Riddle’s Daytona Beach, Florida, campus took t>[...]

ANN's Daily Aero-Term (05.07.24): Hazardous Weather Information

Hazardous Weather Information Summary of significant meteorological information (SIGMET/WS), convective significant meteorological information (convective SIGMET/WST), urgent pilot>[...]

Aero-News: Quote of the Day (05.07.24)

"The need for innovation at speed and scale is greater than ever. The X-62A VISTA is a crucial platform in our efforts to develop, test and integrate AI, as well as to establish AI>[...]

NTSB Final Report: Cessna 150

(FAA) Inspector Observed That Both Fuel Tanks Were Intact And That Only A Minimal Amount Of Fuel Remained In Each Analysis: According to the pilot, approximately 8 miles from the d>[...]

Aero-News: Quote of the Day (05.08.24)

“Pyka’s Pelican Cargo is unlike any other UAS solution on the market for contested logistics. We assessed a number of leading capabilities and concluded that the Pelica>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC