Urgent CASA AD: PZL-104 Aeroplanes - All models

AD/WILGA/4 Elevator Control System Rotational Control Rod 8/2005TX

Applicability: PZL-104 Aeroplanes - All models.

Requirement: 1. Carry out an inspection of the elevator control system rotational control rod, part number (PN) WM261610 for correct security of the adjustment fork end with a safety nut.

2. If the adjustment fork end is secured properly make an entry in the aircraft maintenance log. No further action is required.

3. If the adjustment fork end is not appropriately secured (the safety nut loose, not tightened): a. Secure the adjustment fork end by way of pal-nut tightening; and b. Carry out a check of the adjustment of the control system and elevator deflection angles and carry out any subsequent adjustments; and c. Report the findings to the aircraft manufacturer.

For aeroplanes fitted with a dual control system, rotational control rods must be checked on both controls.

Note: Polish Civil Aviation Office Airworthiness Directive (AD) Number SP-0004-2005-A dated 17 May 2005 refers.

Compliance: 1. Before further flight, after the effective date of this Directive.

2. Following the inspection detailed in Requirement 1 of this Directive.

3. a. Before further flight, following completion of Requirement 1 of this Directive. b. Before further flight, following completion of Requirement 1 of this Directive.

c. Following completion of Requirement 1 of this Directive.

This Airworthiness Directive becomes effective on 14 June 2005.

Background: An accident occurred when the adjustment forked end of the rotational control rod in the elevator control system became loose, resulting in decoupling and blockage of the control system.

The Requirements specified in this AD address the identified unsafe condition.

FMI: http://casa.gov.au/airworth/airwd/NEW/urgent.htm

Advertisement

More News

ANN's Daily Aero-Term (11.29.25): Waypoint

Waypoint A predetermined geographical position used for route/instrument approach definition, progress reports, published VFR routes, visual reporting points or points for transiti>[...]

ANN's Daily Aero-Linx (11.29.25)

Aero Linx: Sentimental Journey to Cub Haven Sentimental Journey Flyin began in 1986 with a group of dedicated volunteers working to provide a sentimental return to Lock Haven, the >[...]

NTSB Prelim: Jabiru USA Sport Aircraft LLC J230-SP

The Pilot Would Often Fly Over Their House At A Low Altitude And That Family Members Would Go Outside To Wave On November 14, 2025, at 1708 eastern standard time, a Jabiru USA Spor>[...]

Classic Aero-TV: Crafting The Future of eVTOL Infrastructure

From 2024 (YouTube Edition): Volatus Infrastructure Paves The Way The name “Volatus” seems to be everywhere these days, popping up in a series of partnerships and proje>[...]

Klyde Morris (11.28.25)

Fortnite Conquers All, Klyde FMI: www.klydemorris.com>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2025 Web Development & Design by Pauli Systems, LC