CASA Urgent AD: Bell Helicopter Textron | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-11.10.25

AirborneNextGen-
11.11.25

Airborne-Unlimited-11.12.25

Airborne-Unlimited-11.06.25

AirborneUnlimited-11.07.25

LIVE MOSAIC Town Hall (Archived): www.airborne-live.net

Sun, Nov 06, 2005

CASA Urgent AD: Bell Helicopter Textron

AD Number: AD/BELL 412/45 Emergency Floatation Reservoir Adapter 13/2005 TX
Applicability: Bell Helicopter Textron Model 412 and 412EP helicopters, modified with Aeronautical Accessories, Inc. (AAI), Supplemental Type Certificate (STC) SH2820SO; or with AAI Parts Manufacturer Approval (PMA) reservoir assembly, part number (P/N) 212-372-050; or with adapter, P/N 212-371-002, installed.
Requirement: 1. Vent the nitrogen from the reservoir assembly by following the Accomplishment Instructions, Part II - Floatation System Discharging, of AAI Alert Service Bulletin (ASB) No. AA-05005, Revision A dated 27 June 27 2005 or later FAA Approved revision.
2. Remove the valve assembly and air line from the adapter, and inspect the counter bore depth (dimension D) as shown in Figure 1 of the ASB.
(a) If dimension D, as depicted in Figure 1 of the ASB, does not exceed .860 inch, recharge the floatation system by following the Accomplishment Instructions, Part III - Floatation System Charging, and referring to Figures 2 and 3 of the ASB.
(b) If dimension D, as depicted in Figure 1 of the ASB, exceeds .860 inch, replace the reservoir assembly and the adapter with serviceable parts.
3. Discharging and recharging the floatation system and inspecting the counter bore depth dimension of the adapter shall be done in accordance with the specified portions of the ASB.

Note: FAA AD 2005-20-38 Amendment 39-14335 refers.

Compliance: 1. Within the next 24 hours time-in-service (TIS) or before the next emergency floatation supply bottle nitrogen charging after the effective date of this AD.
2. Within the next 24 hours time-in-service (TIS) or before the next emergency floatation supply bottle nitrogen charging after the effective date of this AD.
2. (b) Before further flight after the effective date of this AD.
3. From the effective date of this AD.

This Airworthiness Directive becomes effective on 9 November 2005.

Background: The actions detailed in this AD are intended to prevent rupture of an adapter, uncontrolled jetting of pressurized gas from the nitrogen bottle, and subsequent injury to occupants or damage to the helicopter.

FMI: www.casa.gov.au

Advertisement

More News

NTSB Final Report: Piper PA-44-180

While On The Base Leg Of The Airport Traffic Pattern The Right Main Landing Gear Did Not Fully Extend Analysis: Both pilots reported that after performing airwork they returned to >[...]

Classic Aero-TV: The Bizarre Universe of Klyde Morris Cartoons

From 2023 (YouTube Edition): Putting the ANT in Antihero A Beech Starship speeds along at altitude. “Deflectors on!” a voice from within the aircraft cries. “Look>[...]

ANN's Daily Aero-Term (11.09.25): Minimum Friction Level

Minimum Friction Level The friction level specified in AC 150/5320-12, Measurement, Construction, and Maintenance of Skid Resistant Airport Pavement Surfaces, that represents the m>[...]

Aero-News: Quote of the Day (11.09.25)

“Beginning this aircraft subsystem testing is the culmination of more than a decade of focused engineering and certification refinements. This is the moment where our intende>[...]

Classic Aero-TV: Falling for Para-Phernalia’s Softie Emergency Parachutes

From 2023 (YouTube Edition): The Best Option for A Pilots’ Worst Days Since its 1979 founding, Para-Phernalia, Inc. has designed and manufactured the Softie line of pilot eme>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2025 Web Development & Design by Pauli Systems, LC