AD (AUS): Cessna | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-05.05.25

Airborne-NextGen-05.06.25

AirborneUnlimited-05.07.25

Airborne-Unlimited-05.01.25

AirborneUnlimited-05.02.25

Thu, Dec 04, 2003

AD (AUS): Cessna

AWB 27-4 Issue 1, 5 December 2003: Cessna 172, 180 and 185 Primary Flight Control Yoke Inspection

Effectivity: Cessna Aircraft Company and Reims Aviation (Cessna) 172, 180, and 185 series aircraft as listed in the current revision of Cessna Service Bulletin SEB01-3.

Purpose: To alert operators and maintainers to the potential failure of the welded steel tube yoke assembly, which can result in loss of primary pitch control of the aircraft, and to strongly recommend compliance with Cessna Service Bulletin SEB01-3. This SB describes an inspection procedure to detect corrosion, and determine the serviceability of a yoke that has suffered corrosion pitting.

Background: CASA and the FAA have received defect reports describing extensive internal corrosion initiated by moisture collecting inside the lower section of the welded tubular structure. Some control yokes have suffered structural failure due to corrosion in this zone.

The design of the control yoke in the nominated aircraft did not have any provision to drain moisture from the lower section of the yoke. This allowed moisture to collect inside the vertical tube of the assembly, and initiate corrosion. In some cases the corrosion caused a significant reduction of wall thickness of the yoke, and resulted in failure of the lower elevator control lug.

Cessna Aircraft Company has issued instructions for an insitu inspection of the control yoke, which requires an ultrasonic inspection of the lower section of the yoke assembly. Yokes that are corroded beyond the limits prescribed in SEB01-3 should be replaced.

In addition to this, CASA has received a defect report describing internal corrosion deposits outside the nominated area indicated in the Cessna SB, being significantly higher up the vertical tube of the yoke than the shaded area shown in Figure 1 of SEB01-3.

Recommendation: CASA strongly recommends operators and maintainers carry out the requirements of the current revision of Cessna Service Bulletin SEB01-3, extending the zone of eddy current inspection to match the extent of surface corrosion detected, and incorporate the annual inspection requirements of SEB01-3 into the aircraft maintenance program.

FMI: www.casa.gov.au/avreg/aircraft/AWB/27/004.htm, AirworthinessBulletin@casa.gov.au

Advertisement

More News

ANN FAQ: Follow Us On Instagram!

Get The Latest in Aviation News NOW on Instagram Are you on Instagram yet? It's been around for a few years, quietly picking up traction mostly thanks to everybody's new obsession >[...]

Classic Aero-TV: Innovation By Avilution – ‘Pilots Care About Results’

From 2019 (YouTube Edition): Panel Possibilities Range From LSA To eVTOL Aircraft For the most part, pilots care about the information being presented to them rather than how that >[...]

Aero-News: Quote of the Day (05.09.25)

"Flight testing demonstrated significant performance improvements with the Pathfinder-equipped Husky. Compared to the baseline Type Certificated 2-blade Hartzell propeller, the 3-b>[...]

ANN's Daily Aero-Term (05.09.25): Estimated (EST)

Estimated (EST) When used in NOTAMs “EST” is a contraction that is used by the issuing authority only when the condition is expected to return to service prior to the e>[...]

ANN's Daily Aero-Linx (05.09.25)

Aero Linx: Coalition of Airline Pilots Associations (CAPA) The Coalition of Airline Pilots Associations (CAPA) is the world’s largest pilot trade association representing ove>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2025 Web Development & Design by Pauli Systems, LC