Power Flow Systems Offers Improved Cabin Heat for Cessna 172/175 | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-04.28.25

Airborne-NextGen-04.29.25

AirborneUnlimited-04.30.25

Airborne-Unlimited-05.01.25

AirborneUnlimited-05.02.25

Tue, Jun 02, 2020

Power Flow Systems Offers Improved Cabin Heat for Cessna 172/175

Design Enhancement That 'Significantly Increases Cabin Heat Output'

Power Flow Systems has engineered a design enhancement that significantly increases the cabin heat output for their Cessna 172 and 175 second generation exhaust systems (our p/n, PFS-13204). In the original design (dating from 2003), the cool air enters at the front left of the shroud, passes over the internal collector pipes which serve as heat exchangers, then exits to the cabin on the back left side of the shroud.

Unfortunately, they tell us that this was almost a direct straight-through pathway. The Cabin heat SCAT hose connection would then come out of the left side and have to snake its way back to the far right side firewall where the cabin heat mixing valve is located. For most customers, the heat output of the Power Flow was considered to be acceptable, but some flying in extremely cold temperatures told PFS that they wanted an improvement.

With the new design, they have made a vast improvement by relocating the cabin heat output and forcing the air to take a much longer path through the collector assembly which acts as a giant radiator. This forces the air to remain inside the shrouded collector area for longer and greatly increases the available heat inside the aircraft's cabin.

The new design’s output is a 2.0 inch tube that is on the right side of the engine. 2.0 inch SCAT tube, clamps and an adapter to go from 2.0 to 3.0 inches are provided so that the SCAT can travel back in a more direct path to the cabin heat mixing valve on the right side of the firewall.

Ground testing shows that this increased the heat output by 42% over the original Power Flow Systems design (from 100 degrees F to over 140 degrees) and by 27% over the stock Cessna exhaust (from 117 degrees to 140+).

Power Flow Systems Cessna 172/175 kits are now shipping the upgraded cabin heat system. Existing second generation PFS-13204 operators can purchase a complete improved cabin heat retrofit kit - it is our part number PFS-51724 and it is available now.

FMI: www.powerflowsystems.com

Advertisement

More News

ANN's Daily Aero-Linx (04.30.25)

Aero Linx: Aviators Code Initiative (ACI) Innovative tools advancing aviation safety and offering a vision of excellence for aviators. The ACI materials are for use by aviation pra>[...]

ANN FAQ: Turn On Post Notifications

Make Sure You NEVER Miss A New Story From Aero-News Network Do you ever feel like you never see posts from a certain person or page on Facebook or Instagram? Here’s how you c>[...]

Classic Aero-TV: Agile Aero’s Jeff Greason--Disruptive Aerospace Innovations

From 2016 (YouTube Edition): Who You Gonna Call When You Have a Rocket Engine that Needs a Spacecraft? While at EAA AirVenture 2016, ANN CEO and Editor-In-Chief, Jim Campbell, sat >[...]

Aero-News: Quote of the Day (04.30.25)

"In my opinion, if this isn't an excessive fine, I don't know what is... The odds are good that we're gonna be seeking review in the United States Supreme Court. So we gotta muster>[...]

ANN's Daily Aero-Term (04.30.25): Expedite

Expedite Used by ATC when prompt compliance is required to avoid the development of an imminent situation. Expedite climb/descent normally indicates to a pilot that the approximate>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2025 Web Development & Design by Pauli Systems, LC