Power Flow Systems Offers Improved Cabin Heat for Cessna 172/175 | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-06.23.25

Airborne-NextGen-06.24.25

AirborneUnlimited-06.25.25

Airborne-AffordableFlyers-06.26.25

AirborneUnlimited-06.27.25

Tue, Jun 02, 2020

Power Flow Systems Offers Improved Cabin Heat for Cessna 172/175

Design Enhancement That 'Significantly Increases Cabin Heat Output'

Power Flow Systems has engineered a design enhancement that significantly increases the cabin heat output for their Cessna 172 and 175 second generation exhaust systems (our p/n, PFS-13204). In the original design (dating from 2003), the cool air enters at the front left of the shroud, passes over the internal collector pipes which serve as heat exchangers, then exits to the cabin on the back left side of the shroud.

Unfortunately, they tell us that this was almost a direct straight-through pathway. The Cabin heat SCAT hose connection would then come out of the left side and have to snake its way back to the far right side firewall where the cabin heat mixing valve is located. For most customers, the heat output of the Power Flow was considered to be acceptable, but some flying in extremely cold temperatures told PFS that they wanted an improvement.

With the new design, they have made a vast improvement by relocating the cabin heat output and forcing the air to take a much longer path through the collector assembly which acts as a giant radiator. This forces the air to remain inside the shrouded collector area for longer and greatly increases the available heat inside the aircraft's cabin.

The new design’s output is a 2.0 inch tube that is on the right side of the engine. 2.0 inch SCAT tube, clamps and an adapter to go from 2.0 to 3.0 inches are provided so that the SCAT can travel back in a more direct path to the cabin heat mixing valve on the right side of the firewall.

Ground testing shows that this increased the heat output by 42% over the original Power Flow Systems design (from 100 degrees F to over 140 degrees) and by 27% over the stock Cessna exhaust (from 117 degrees to 140+).

Power Flow Systems Cessna 172/175 kits are now shipping the upgraded cabin heat system. Existing second generation PFS-13204 operators can purchase a complete improved cabin heat retrofit kit - it is our part number PFS-51724 and it is available now.

FMI: www.powerflowsystems.com

Advertisement

More News

ANN's Daily Aero-Linx (06.29.25)

Aero Linx: Transport Canada We are a federal institution, leading the Transport Canada portfolio and working with our partners. Transport Canada is responsible for transportation p>[...]

ANN's Daily Aero-Term (06.29.25): Gross Navigation Error (GNE)

Gross Navigation Error (GNE) A lateral deviation from a cleared track, normally in excess of 25 Nautical Miles (NM). More stringent standards (for example, 10NM in some parts of th>[...]

Classic Aero-TV: Anticipating Futurespace - Blue Origin Visits Airventure 2017

From AirVenture 2017 (YouTube Edition): Flight-Proven Booster On Display At AirVenture… EAA AirVenture Oshkosh is known primarily as a celebration of experimental and amateu>[...]

NTSB Final Report: Cirrus SR22

Aircraft Parachute System (CAPS) Was Deployed About 293 Ft Above Ground Level, Which Was Too Low To Allow For Full Deployment Of The Parachute System Analysis: The day before the a>[...]

Airborne Affordable Flyers 06.26.25: PA18 Upgrades, ‘Delta Force’, Rhinebeck

Also: 48th Annual Air Race Classic, Hot Air Balloon Fire, FAA v Banning 100LL, Complete Remote Pilot The news Piper PA-18 Super Cub owners have been waiting for has finally arrived>[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2025 Web Development & Design by Pauli Systems, LC