Sun, Jun 27, 2021
AD 2021-11-07 Requires Inspection Of The Stages 6-10 Compressor Rotor Spool
The FAA is adopting a new airworthiness directive (AD) for certain General Electric Company (GE) GEnx-1B64, 1B64/P1, -1B64/P2, -1B67, -1B67/P1, -1B67/P2, -1B70, -1B70/75/P1, -1B70/75/P2, -1B70/P1, -1B70/P2, -1B70C/P1, -1B70C/P2, -1B74/75/P1, -1B74/75/P2, -1B76/P2, -1B76A/P2, -2B67, -2B67/P, and -2B67B model turbofan engines.

This AD was prompted by a finding during an inspection by the manufacturer that two stages 6-10 compressor rotor spools in the high-pressure compressor (HPC) assembly were damaged at similar locations. Additionally, the manufacturer reported that certain stages 6-10 compressor rotor spool webs did not undergo a required fluorescent penetrant inspection (FPI) during production. This AD requires inspection of the stages 6-10 compressor rotor spool and, depending on the results of the inspection, replacement of the stages 6-10 compressor rotor spool. The FAA is issuing this AD to address the unsafe condition on these products. This AD is effective July 30, 2021.
In the NPRM, the FAA proposed to require inspection of the stages 6-10 compressor rotor spool. Operators of certain affected GEnx-1B or GEnx-2B model turbofan engines have already completed acceptable inspections of the aft web of stage 6, stage 7, and stage 8 of the stages 6-10 compressor rotor spool. The FAA proposed to require operators of those affected engines to complete the inspection of the stages 6-10 compressor rotor spool no later than the next engine shop visit. The FAA proposed to require all other remaining affected GEnx-1B and GEnx-2B model turbofan engines to complete this inspection by the next engine shop visit, before the stages 6-10 compressor rotor spools accumulate 6,500 cycles since new, or before further flight if 6,500 cycles since new has already been accumulated as of the effective date of this AD. Depending on the results of the inspection, the FAA proposed to require replacement of the stages 6-10 compressor rotor spool with a part eligible for installation. The FAA
is issuing this AD to address the unsafe condition on these products.
More News
Outboard Section Of The Right Wing And The Right Flap Separated In Flight And The Airplane Impacted A Farm Field Analysis: The pilot was approaching his destination airport under i>[...]
Final Approach Fix The fix from which the final approach (IFR) to an airport is executed and which identifies the beginning of the final approach segment. It is designated on Gover>[...]
"Our choice of when to respond, how to respond and on which targets to respond is a consideration that we make every time... Netanyahu also noted that anyone attacking Israel &ldqu>[...]
Estimated (EST) When used in NOTAMs “EST” is a contraction that is used by the issuing authority only when the condition is expected to return to service prior to the e>[...]
Aero Linx: Coalition of Airline Pilots Associations (CAPA) The Coalition of Airline Pilots Associations (CAPA) is the world’s largest pilot trade association representing ove>[...]