CASA Urgent AD: Bell Helicopter Textron | Aero-News Network
Aero-News Network
RSS icon RSS feed
podcast icon MP3 podcast
Subscribe Aero-News e-mail Newsletter Subscribe

Airborne Unlimited -- Most Recent Daily Episodes

Episode Date

Airborne-Monday

Airborne-Tuesday

Airborne-Wednesday Airborne-Thursday

Airborne-Friday

Airborne On YouTube

Airborne-Unlimited-06.03.24

Airborne-NextGen-06.04.24

Airborne-Unlimited-06.05.24 Airborne-Unlimited-05.30.24

Airborne-Unlimited-05.24.24

Sun, Nov 06, 2005

CASA Urgent AD: Bell Helicopter Textron

AD Number: AD/BELL 412/45 Emergency Floatation Reservoir Adapter 13/2005 TX
Applicability: Bell Helicopter Textron Model 412 and 412EP helicopters, modified with Aeronautical Accessories, Inc. (AAI), Supplemental Type Certificate (STC) SH2820SO; or with AAI Parts Manufacturer Approval (PMA) reservoir assembly, part number (P/N) 212-372-050; or with adapter, P/N 212-371-002, installed.
Requirement: 1. Vent the nitrogen from the reservoir assembly by following the Accomplishment Instructions, Part II - Floatation System Discharging, of AAI Alert Service Bulletin (ASB) No. AA-05005, Revision A dated 27 June 27 2005 or later FAA Approved revision.
2. Remove the valve assembly and air line from the adapter, and inspect the counter bore depth (dimension D) as shown in Figure 1 of the ASB.
(a) If dimension D, as depicted in Figure 1 of the ASB, does not exceed .860 inch, recharge the floatation system by following the Accomplishment Instructions, Part III - Floatation System Charging, and referring to Figures 2 and 3 of the ASB.
(b) If dimension D, as depicted in Figure 1 of the ASB, exceeds .860 inch, replace the reservoir assembly and the adapter with serviceable parts.
3. Discharging and recharging the floatation system and inspecting the counter bore depth dimension of the adapter shall be done in accordance with the specified portions of the ASB.

Note: FAA AD 2005-20-38 Amendment 39-14335 refers.

Compliance: 1. Within the next 24 hours time-in-service (TIS) or before the next emergency floatation supply bottle nitrogen charging after the effective date of this AD.
2. Within the next 24 hours time-in-service (TIS) or before the next emergency floatation supply bottle nitrogen charging after the effective date of this AD.
2. (b) Before further flight after the effective date of this AD.
3. From the effective date of this AD.

This Airworthiness Directive becomes effective on 9 November 2005.

Background: The actions detailed in this AD are intended to prevent rupture of an adapter, uncontrolled jetting of pressurized gas from the nitrogen bottle, and subsequent injury to occupants or damage to the helicopter.

FMI: www.casa.gov.au

Advertisement

More News

Airborne 06.05.24: Yakstars Midair, Electra eSTOL Test, Space Tour No-Go

Also: Aerox 'Cylinder Sentinel', Annual TBM Reunion, Hubble Pause, Utah AAM A combined Spanish-Portuguese aerobatic demo team suffered a fatality at the Beja AirShow, when one of t>[...]

Classic Aero-TV: Aviation Prop Masters--Hartzell Composite Props for the KingAir

From 2019 (YouTube Version): Hartzell Propeller Secures STC For King Air Propellers Hartzell Propeller has secured an FAA Type Certificate for a new five-blade carbon fiber propell>[...]

Aero-News: Quote of the Day (06.03.24)

"Starship’s third flight test made tremendous strides towards a future of rapidly reliable reusable rockets. The test completed several exciting firsts, including the first S>[...]

ANN's Daily Aero-Linx (06.03.24)

Aero Linx: Utah Back Country Pilots Association (UBCP) We hope to promote flying in Utah, and we welcome you to our state. We recognize the inherent hazards and risk involved in ba>[...]

ANN's Daily Aero-Term (06.03.24):Maximum Authorized Altitude

Maximum Authorized Altitude A published altitude representing the maximum usable altitude or flight level for an airspace structure or route segment. It is the highest altitude on >[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC