Sun, May 30, 2021

AD: ATR-GIE Avions de Transport Régional Airplanes

AD 2021-09-18 Requires Modifying The Electrical Harness Routes And De-Icing Pipe Coupling Installations

The FAA is adopting a new airworthiness directive (AD) for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

This AD was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. This AD requires modifying the electrical harness routes and de-icing pipe coupling installations, as specified in a European Union Aviation Safety Agency (EASA) AD, which is incorporated by reference. The FAA is issuing this AD to address the unsafe condition on these products. This AD is effective July 1, 2021.

Supplementary Information: The EASA, which is the Technical Agent for the Member States of the European Union, has issued EASA AD 2020-0227, dated October 19, 2020 (EASA AD 2020-0227) (also referred to as the Mandatory Continuing Airworthiness Information, or the MCAI), to correct an unsafe condition for certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes.

The FAA issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 by adding an AD that would apply to certain ATR-GIE Avions de Transport Régional Model ATR72-212A airplanes. The NPRM published in the Federal Register on February 22, 2021 (86 FR 10491). The NPRM was prompted by a report of an engine electrical control #1 fault during flight caused by chafing damage on an electrical harness bundle. The NPRM proposed to require modifying the electrical harness routes and de-icing pipe coupling installations, as specified in EASA AD 2020-0227.

The FAA is issuing this AD to address chafing damage on an electrical harness bundle, which could result in wire failure and a short circuit, an uncontrolled fire, and consequent loss of multiple systems, possibly resulting in reduced controllability of the airplane. See the MCAI for additional background information.

FMI: www.regulations.gov

Advertisement

More News

ANN's Daily Aero-Term (05.10.24): Takeoff Roll

Takeoff Roll The process whereby an aircraft is aligned with the runway centerline and the aircraft is moving with the intent to take off. For helicopters, this pertains to the act>[...]

Aero-News: Quote of the Day (05.10.24)

“We’re proud of the hard work that went into receiving this validation, and it will be a welcome relief to our customers in the European Union. We couldn’t be mor>[...]

Airborne 05.06.24: Gone West-Dick Rutan, ICON BK Update, SpaceX EVA Suit

Also: 1800th E-Jet, Uncle Sam Sues For Landing Gear, Embraer Ag Plane, Textron Parts A friend of the family reported that Lt. Col. (Ret.) Richard Glenn Rutan flew west on Friday, M>[...]

Airborne 05.03.24: Advanced Powerplant Solutions, PRA Runway Woes, Drone Racing

Also: Virgin Galactic, B-29 Doc to Allentown, Erickson Fire-Fighters Bought, FAA Reauthorization After dealing with a big letdown after the unexpected decision by Skyreach to disco>[...]

Aero-News: Quote of the Day (05.11.24)

"Aircraft Spruce is pleased to announce the acquisition of the parts distribution operations of Wag-Aero. Wag-Aero was founded in the 1960’s by Dick and Bobbie Wagner in the >[...]

blog comments powered by Disqus



Advertisement

Advertisement

Podcasts

Advertisement

© 2007 - 2024 Web Development & Design by Pauli Systems, LC